Dynamic balancing machine calibration steps

Dynamic balancing machine calibration steps

Page view
[Abstract]:
In rotating machinery, the rotor is a very important part of it. Therefore, to ensure the uniform mass distribution of the rotor, it is necessary to use a dynamic balancing machine for verification. T

In rotating machinery, the rotor is a very important part of it. Therefore, to ensure the uniform mass distribution of the rotor, it is necessary to use a dynamic balancing machine for verification. The cause of the rotor imbalance can be specified according to the standard: the imbalance is Due to the uneven distribution of the rotor mass, the rotor generates centrifugal force during the rotation process, which causes the mechanical vibration to mainly act on the bearing. Therefore, the uneven distribution of the rotor mass is one of the important factors causing the rotor imbalance. When we talk about the balancing machine, we must first calibrate it. What are the calibration steps of the balancing machine?

 

 

1. Open the calibration dialog box and enter the weight of the test weight by 0.5g and the angle of 0 degrees. If the left and right corrections should be entered at the same time.
2. Add 0.5g plasticine at 0° on the left calibration surface of the groove according to the weight and angle input on the left side. Do not increase the weight on the right correction surface. Click the calibration measurement button.
3. Start the slot by driving, wait for the lock button to turn green, and start the measurement after unlocking. After the measurement time is completed, lock the car to stop the slot.
4. Press the weight and angle entered on the right side to add 0.5g plasticine to the right correction surface of the drum. The left correction surface is not emphasized. Click the calibration measurement button.
5. Start the slot by driving, wait for the lock button to turn green, and start the measurement after unlocking. After the measurement time is completed, lock the car to stop the slot.
6. Do not add test weight to the left and right calibration surfaces, click the calibration measurement button.
7. Start the slot by driving, wait for the lock button to turn green, and start the measurement after unlocking. After the measurement time is completed, lock the car to stop the slot.
8. Click the calibration completion button and the calibration process ends.